Volume 4, Issue 1 (Journal OF Welding Science and Technology of Iran 2018)                   JWSTI 2018, 4(1): 29-41 | Back to browse issues page

XML Persian Abstract Print


1- Department of Mining and Metallurgical Engineering, Amirkabir University of Technology, Tehran, Iran
2- Iranian Gas Engineering and Development Co.
Abstract:   (5629 Views)
In this study, first,diffusible hydrogen of cellulosic electrode E8010-P1 and low hydrogen electrode E8018-G was measured by mercury displacement method according to ISO3690. Then,the effect of preheating and post-heating on the sensitivity to hydrogen inducedcold cracking in welding of 18mm API5L X70 steel with these electrodes was investigated according to ISO17642-2. The results of visual inspection, penetrant test,metallographic examination, and hardness test showed that welding with cellulosic electrode leads to cracking unless both preheating and post-heating are applied.While in the case of low hydrogen electrode, cracking occurs only if no preheating or post-heating is applied.
 
Full-Text [PDF 8650 kb]   (1397 Downloads)    
Type of Study: Research | Subject: Special

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.